firmware Update

The current (official) OpenSprinkler Firmware is available here:

Click link

BACKUP YOUR SETTINGS BEFORE UPDATE!

Depending on the old version, your OpenSprinkler perform a reset and reset all settings. Therefore, you should back up your settings first. In the menu in the app or web interface there is “Export configuration” to save and “Import configuration” to import the backup again.

The default password is “opendoor” and should be changed!

Attention: If you are attempting to update a new, unconfigured device or a device that has just undergone a factory reset, the password will not be accepted.

The reason is the lack of online access to be able to run the md5 function for the password. Use the password here

a6d82bced638de3def1e9bbb4983225c

This corresponds to the md5 hash of “opendoor”.

OSPI

An update with the OSPi is simple: log in to your Raspberry PI, switch to the “OpenSprinkler-Firmware” directory and start updater.sh (with ./updater.sh or sudo ./updater.sh)

OPENSPRINKLER 3/3.2 AC/DC

The OpenSprinkler with ethernet: The firmware update can ONLY be carried out via WLAN (for versions lower than 2.2.0.105). Disconnect the Ethernet network connection by unplugging the Ethernet module from the cable and start the OpenSprinkler by holding B2, then confirm with B3, new

Save your settings! You can save the settings as a file with "Export configuration" in the menu at the top left!

Now download the latest firmware from the link above. The file must end with .bin. If it is a .zip, it must first be unpacked.

Click on B1 to enter the IP of your OpenSprinklers to determine. Start your web browser and enter:

http://<ipadresse>/update

Where you replace with the IP.

1. Click “Browse…” and select the firmware file downloaded above.

2. Underneath, enter the password of their OpenSprinklerbe.

3. Click on “Submit” (do not press return or enter! You have to click on “Submit”!)

4. Watch hers OpenSprinkler: After a few seconds “Rebooting” should appear and OpenSprinkler reboots.

5. Done. Depending on the firmware version, you may have to read back the settings. You can do this with the "Import configuration" menu at the top left.

 

 

Another tip, if OpenSprinkler now no longer boots:

Factory reset: While booting the controller, press and hold B1+B2 until you see “Factory Reset” on the screen. Select “Yes” and then press and hold B3. A hardware reset will be triggered and the controller will revert to default settings.

 

4 opinions on “firmware Update"

Leave a Comment

Your e-mail address will not be published. Required fields are marked with * marked

This website uses Akismet to reduce spam. Learn more about how your comment data is processed.